{"product_id":"mobil-shc-aware-h-32-pail-20ltr-152377","title":"Mobil SHC AWARE H 32 PAIL 20Ltr","description":"\u003ch4\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMobil SHC Aware H Series lubricants are high performance, anti-wear hydraulic oils for modern high pressure hydraulic systems that meet the U.S.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e Environmental Protection Agency (EPA) 2013 Vessel General Permit (VGP) guidelines for \"environmentally acceptable lubricants\".\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e They provide excellent wide temperature range performance above and beyond the capabilities of non-synthetic environmentally acceptable oils.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e Mobil SHC Aware H Series oils are specially formulated from ester base stocks and provide exceptional anti-wear and film strength characteristics necessary for hydraulic systems operating under high load and high pressures.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecification and Approvals\u003c\/strong\u003e\u003c\/p\u003e\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProperty\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e32\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e46\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e68\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eGrade\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eISO 32\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eISO 46\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eISO 68\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eAcute Algae Toxicity, EC50\/72h, mg\/l, OECD 201\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt;1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt;1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt;1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eAcute Daphnia Toxicity, EC50\/48h, mg\/l, OECD 202\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt;1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt;1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt;1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eAcute Fish Toxicity, LC50\/96h, mg\/l, OECD 203\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt;1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt;1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt;1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eBioaccumulation, Partition Coefficient, Log Pow, OECD 117\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026lt;3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026lt;3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026lt;3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eDensity @ 15 C, g\/ml, ASTM D4052\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0.912\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0.905\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0.915\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eFZG Scuffing, Fail Load Stage, A\/8.3\/90, ISO 14635-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e11\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e12\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt;12\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eFlash Point, Cleveland Open Cup, °C, ASTM D92\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e185\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e185\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e185\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eKinematic Viscosity @ 100 C, mm2\/s, ASTM D445\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e8.2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e10.37\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eKinematic Viscosity @ 40 C, mm2\/s, ASTM D445\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e32\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e46\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e68\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePour Point, °C, ASTM D97\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e-54\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e-36\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e-36\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eRust Test, Sea Water, 24 h @ 60 C, ASTM D665-PROB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePASS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePASS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePASS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eShake-Flask Test, CO2 Evolution (Mod. Sturm), %, OECD 301B\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt;60\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt;60\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u0026gt;60\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eViscosity Index, ASTM D2270\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e140\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e140\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e140\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e Marine controllable pitch propellers (CPP) systems, fin stabilizers, deck equipment, hydraulic systems where spills or leakage could result in adverse environment impact\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e In systems where readily biodegradable and minimally toxic fluids may be required\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Circulation systems containing gears and bearings where mild extreme-pressure characteristics are desired\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Systems containing servo-valves\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Hydraulic systems operating with oil temperatures in the range of -30C to +100C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Marine and mobile equipment operating in environmentally sensitive areas\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Circulation systems operating under mild to moderate service conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Industrial hydraulic systems where leaked or spilled fluids could get into plant effluent\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Air line oilers and some limited oil-mist generating systems\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003ePlease compare with your original manufacturer's oil specification which can be found in your vehicle manual. Feel free to contact us  if you require any assistance!\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\u003ch4\u003eCompatibility Check\u003c\/h4\u003e\n\u003cp\u003eTo ensure the part(s) you have ordered fits your vehicle, we run a compatibility check prior to dispatch. We can do this either using your license plate or the last 7 digits of your VIN. Simply enter your\ncar details prior to checkout.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\u003ch4\u003e\u003cstrong\u003e Part Number \u003c\/strong\u003e\u003c\/h4\u003e\u003cp\u003e\nMOBIL152377\n\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003ch4\u003e\u003cstrong\u003eMore Information\u003c\/strong\u003e\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003e Manufactured by\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMobil\u003c\/p\u003e","brand":"Mobil","offers":[{"title":"Default Title","offer_id":48680179728609,"sku":"MOBIL152377","price":474.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0842\/7608\/4961\/files\/1r5-AaGFoUsENoi1uSDvSvLzhGdwrZZ4I_70f5b4ec-6284-4126-94f8-dc2f8dfad5fa.jpg?v=1784645094","url":"https:\/\/mlperformanceusa.com\/products\/mobil-shc-aware-h-32-pail-20ltr-152377","provider":"ML Performance USA","version":"1.0","type":"link"}